Line 5: Line 5:
 
The relay timing of the Art Controller is performed by the internal clock of the on-board microcontroller, and the delay time is configured with the DIP switches. Using the DIP switches, it is possible to select delay periods ranging from 1 second to 31 hours.
 
The relay timing of the Art Controller is performed by the internal clock of the on-board microcontroller, and the delay time is configured with the DIP switches. Using the DIP switches, it is possible to select delay periods ranging from 1 second to 31 hours.
  
The DIP switches have five numeric values (1, 2, 4, 8, and 16 seconds), and three multipliers (×6, ×10, and ×60). The numeric part can be adjusted to add up to any value between 1 s and 31 s, and the multipliers allow these values to be scaled up into the following ranges of nominal delay times:
+
The DIP switches have five numeric values (1, 2, 4, 8, and 16 seconds), and three multipliers (×6, ×10, and ×60). The numeric part can be adjusted to add up to any value between 1 s and 31 s, and the multipliers allow these values to be scaled up into the following ranges of nominal delay times:
 
 
 
 
* 1 s — 31 s, in 1 second increments. <br />
 
:If none of the three multipliers is turned on, the delay time in seconds is given by the sum of the switches that are on; a value that can range between 1 and 31.  Note that the minimum value of the delay is 1 s; if you select a delay of "0," it will give the same result as though you has selected a value of 1.
 
 
 
* 6 s — 186 s (3 minutes and 6 seconds), in 6 second increments. 
 
:To enter this range, turn on only the &times;6 multiplier.
 
  
 +
* 1 s — 31 s
 +
* 6 s — 186 s (3 minutes and 6 seconds), in 6 second increments
 
* 10 s — 310 s (5 minutes and 10 seconds), in 10 second increments
 
* 10 s — 310 s (5 minutes and 10 seconds), in 10 second increments
:To enter this range, turn on only the &times;10 multiplier.
 
 
 
* 1 m — 31 m, in 1 minute increments
 
* 1 m — 31 m, in 1 minute increments
:To enter this range, turn on only the &times;60 multiplier.
 
 
 
* 6 m — 186 m (3 hours and 6 minutes), in 6 minute increments
 
* 6 m — 186 m (3 hours and 6 minutes), in 6 minute increments
:To enter this range, turn on the &times;6 and &times;60 multipliers.
 
 
 
* 10 m — 310 m (5 hours and 10 minutes), in 10 minute increments
 
* 10 m — 310 m (5 hours and 10 minutes), in 10 minute increments
:To enter this range, turn on the &times;10 and &times;60 multipliers.
 
 
 
* 1 h — 31 h, in 1 hour increments
 
* 1 h — 31 h, in 1 hour increments
:To enter this range, turn on all three (&times;6, &times;10, and &times;60) multipliers.
 
 
 
 
Please note that all delay times are approximate. While delay times specified with the DIP switches are typically quite accurate near room temperature, the exact period does depend on operating temperature and can vary by as much as ±10%, towards the edges of the operating temperature range, -40°C to 85°C.  
 
Please note that all delay times are approximate. While delay times specified with the DIP switches are typically quite accurate near room temperature, the exact period does depend on operating temperature and can vary by as much as ±10%, towards the edges of the operating temperature range, -40°C to 85°C.  
  
Line 57: Line 41:
 
* Repeat. You can solder a wire between this pin and ground to configure this option. Normally, when the Art Controller receives a trigger, it energizes the coil for the specified delay time and then goes back to the idle state. When the repeat option is configured, a trigger instead begins a continuous cycle where the coil is alternately energized and off, each for the specified delay period. The cycle can be halted by using the Cancel input, by pressing the trigger again (if Start/Stop on Trigger is configured), or by removing power from the Art Controller.
 
* Repeat. You can solder a wire between this pin and ground to configure this option. Normally, when the Art Controller receives a trigger, it energizes the coil for the specified delay time and then goes back to the idle state. When the repeat option is configured, a trigger instead begins a continuous cycle where the coil is alternately energized and off, each for the specified delay period. The cycle can be halted by using the Cancel input, by pressing the trigger again (if Start/Stop on Trigger is configured), or by removing power from the Art Controller.
  
 
+
Mechanical relays and configuration: The relay on the Art Controller is an electromechanical type: A mechanical switch that is flipped by an electromagnet when energized.
'''Mechanical relays and configuration:'''
 
 
 
The relay on the Art Controller is an electromechanical type: A mechanical switch that is flipped by an electromagnet when energized.
 
  
 
The relay is an "SPDT" type, meaning that it can be used either as a normally-open or normally-closed relay. When idle, the "Common" terminal of the output terminal block is connected to the "NC" terminal, and when the coil is energized, the "Common" terminal is instead connected to the "NO" terminal. When power is removed from the coil (or from the Art Controller as a whole), the relay reverts to its idle state.
 
The relay is an "SPDT" type, meaning that it can be used either as a normally-open or normally-closed relay. When idle, the "Common" terminal of the output terminal block is connected to the "NC" terminal, and when the coil is energized, the "Common" terminal is instead connected to the "NO" terminal. When power is removed from the coil (or from the Art Controller as a whole), the relay reverts to its idle state.

Please note that all contributions to Evil Mad Scientist Wiki are considered to be released under the GNU Free Documentation License 1.3 (see Evil Mad Scientist Wiki:Copyrights for details). If you do not want your writing to be edited mercilessly and redistributed at will, then do not submit it here.